Anmol Chemicals is the pioneer manufacturers of Chromium Picolinate, Pharmaceutical Excipients Chemicals in India. We offer Halal and Kosher Chromic Picolinate made in an ISO9001, ISO22000 (FSSC22000) cGMP and GLP certified facility. Our group has several manufacturing facilities spread across the world, supported by toll manufacturers and representatives in UAE, Europe, USA, China and has several associated manufacturing facilities spread across India. All the Information on Physics, Chemistry, Applications, Uses and Technology on Manufacture of Chromium Picolinate is in these pages.
The units have one or more of the certifications like FDA GMP, ISO 9001, ISO 22000, HACCP, REACH, Kosher & Halal

Home ------------ Contact

Drum Packing Palletized Drum Packing 25-50kg or 55lbs bags. Paletized and Shrink Wrapped. Exports to USA UAE Europe South Africa Tanzania Kenya Egypt Uganda Turkey Brazil Chile Argentina Dubai. Jumbo Bag Packing Chromium Picolinate Manufacturers

Chromium Picolinate USP Grade Manufacturers

Chromium Picolinate SDS GHS of Manufacturers

Chromium Picolinate CAS Number 14639-25-9, Molecular Weight: 418.33,Chemical Formula: Cr(C6H4NO2)3

Chromium Picolinate USP Grade
C18H12N3O6Cr -- 418.31
Chromium Tripicolinate.
Chromium Picolinate contains not less than 98.0 percent and not more than 102.0 percent of C18H12N3O6Cr, calculated on the dried basis.

Identification:
A: Infrared Absorption.
B: To 5 mL of a solution (1 in 250) in a test tube add 1 mL of 5 N sodium hydroxide and 10 drops of 30% hydrogen peroxide, and heat gently for about 2 minutes: a yellow color develops.
Loss on drying: Dry it at 105C for 4 hours: it loses not more than 4.0% of its weight.
Chloride: Dissolve 30 mg of Chromium Picolinate in 30 to 40 mL of water, and heat to 70C. Cool overnight, and filter to remove the precipitate. Add 1 mL each of nitric acid and silver nitrate TS, and add sufficient water to make 50 mL. Mix, and allow to stand for 5 minutes, protected from direct sunlight: any turbidity formed is not greater than that produced in a similarly treated control solution containing 0.25 mL of 0.002 N hydrochloric acid (0.06%).
Sulfate: Dissolve 100 mg of Chromium Picolinate in 30 to 40 mL of water, and heat to 90C. Cool overnight, and filter to remove the precipitate. Add 1 mL of 3 N hydrochloric acid, 3 mL of barium chloride, and sufficient water to make 50 mL. Mix, and allow to stand for 10 minutes: any turbidity formed is not greater than that produced in a similarly treated control solution containing 0.2 mL of 0.02 N sulfuric acid (0.2%).

Assay:
Standard stock solution: Transfer about 0.283 g of potassium dichromate, previously dried at 120C for 4 hours and accurately weighed, to a 1000-mL volumetric flask, dissolve in and dilute with water to volume to obtain a solution having a known concentration of about 100 µg of chromium per mL, and mix. Store in a polyethylene bottle.
Standard preparations: Separately transfer 1.0 mL and 2.0 mL of the Standard stock solution to 100-mL volumetric flasks, and transfer 1.5 mL and 2.0 mL of the Standard stock solution to separate 50-mL volumetric flasks. Add 1.0 mL of nitric acid to each flask, dilute the contents of each flask with water to volume, and mix. These Standard preparations contain 1.0, 2.0, 3.0, and 4.0 µg of chromium per mL, respectively.
Assay preparation: Transfer about 200 mg of Chromium Picolinate, accurately weighed, to a 500-mL volumetric flask, and add 25 mL of water. Slowly add 10 mL of nitric acid, and boil for 10 minutes with constant swirling. Cool the solution, dilute with water to volume, and mix. Filter a portion of the solution, and transfer 5 mL of the filtrate to a 100-mL volumetric flask. Add 1 mL of nitric acid, dilute with water to volume, and mix.
Procedure: Concomitantly determine the absorbances of the Standard preparations and the Assay preparation at the chromium emission wavelength of 357.9 nm, with a suitable atomic absorption spectrophotometer equipped with a chromium hollow-cathode lamp and an air–acetylene flame, using diluted nitric acid as the blank. Plot the absorbances of the Standard preparations versus chromium concentration, in µg per mL, and draw the straight line best fitting the four plotted points. From the graph so obtained, determine the chromium concentration, in µg per mL, in the Assay preparation. Calculate the quantity, in mg, of C18H12N3O6Cr in the portion of Chromium Picolinate taken by the formula:
(418.31 / 51.996)(10C)
in which C is the concentration, in µg per mL, of chromium in the Assay preparation; 418.31 is the molecular weight of chromium picolinate; and 51.996 is the atomic weight of chromium.

We offer as under:

Chromium Acetate

Chromium Chloride

Chromium Picolinate.

Chromium Picolinate USP Manufacturers at:

Anmol Chemicals
S-8, SARIFA MANSION, 2ND FLANK ROAD, CHINCHBUNDER, MUMBAI 400009, INDIA
TEL: (OFFICE) 91-22-23770100, 23726950, 23774610, 23723564. FAX: 91-22-23728264

e-mail: anmolc@mtnl.net.in

Manufacturers India

Exports to USA, Canada, UAE, Dubai, South Africa, Tanzania, Kenya, Nigeria, Egypt, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Europe Netherlands, Italy, Spain, Germany, Portugal, France, Malaysia, Indonesia, Thailand, Georgia, Korea, Japan, etc.

Copyright and Usual Disclaimer is Applicable 4 March, 2022